Before you can start using the terminal, you need to change multiple settings of the printing device. The location of these settings on the printing device's Web UI slightly varies depending on the OSA platform.

The following sections describe the setup in two types of the Web UI: the legacy interface of the OSA 4.5 platform, and the modern interface of the OSA 5.0+ platform.

Configuration on the legacy interface

  1. Log on the printing device's Web User Interface as an administrator (http://*IP Address of the device*).

  2. On the menu on the left side of the Web UI screen, click Application Settings. The Application Settings drop-down menu opens.

    4.5 web UI - Opening application settings
  3. On the menu, click External Application Settings. The External Application Settings drop-down menu opens.

    4.5 web UI - Opening external application settings
  4. On the menu, click External Accounting Application Settings. The External Application Settings tab opens to the right.

    4.5 web UI - Opening external accounting application settings
  5. On the tab, enable External Account Control (External Account Control = Enable), and then select the Set Authentication Server (Server1) option. Additional settings become available.

    Device web UI - external accounting application settings
  6. Make sure that the Server 1 setting is enabled (Server 1=Enable), and then fill in the following:

    1. Application Name: MyQ

    2. Address for Application UI: http://*MyQServerIP*:*Port*/package/sharp/app/home/dispatch
      (MyQServerIP is the IP address or hostname of the MyQ server and Port is the MyQ server port).

    3. Address for Web Service: http://*MyQ ServerIP*:Port/package/sharp/soap/MFPSoapWS
      (MyQServerIP is the IP address or hostname of the MyQ server and Port is the MyQ server port).

    4. Select the Extended Platform option.

    5. Set the Display Style to Full.

  7. Click Submit at the top left corner of the tab. When you are asked to reboot the device, click Reboot Later(O) to submit the changes.

  8. On the menu, under External Application Settings, click Standard Application Settings. The Standard Application Settings tab opens.

    4.5 web UI - Opening standard application settings
  9. Check if the MyQ application is displayed on the tab.

    1. If it is not, click Add(Y) to create it.

      4.5 web UI - Add application
    2. If it is, click MyQ to open the application's settings.

      4.5 web UI - MyQ application
  10. On the tab, set the following options:

    Device web UI - standard application registration
    1. Application Name: MyQ

    2. Address for Application UI: http://*MyQServerIP*:*Port*/package/sharp/app/acm
      (MyQServerIP is the IP address or hostname of the MyQ server, and Port is the MyQ server port).

    3. Enable the Extended Platform option, and set the Display Style to Full.

  11. Click Submit(U). When you are asked to reboot the device, click Reboot Now(C) to submit the changes and reboot the device.